Design of steel sheathed cold-formed steel framed shear walls
نویسندگان
چکیده
منابع مشابه
Analysis of Sheathed Cold-Formed Steel Wall Studs
The strength of sheathed wall systems is substantially greater than unsheathed walls with the same studs. Testing on studs sheathed on both sides with dry gypsum board demonstrate strength increases as large as 70% over unsheathed studs (Miller and Peköz 1993, Miller and Peköz 1994). The current AISI Specification for sheathed wall stud systems are complicated, only apply when the sheathing is ...
متن کاملBracing Stiffness and Strength in Sheathed Cold-formed Steel Stud Walls
The objective of this paper is to provide the stiffness and strength characteristics for coldformed steel stud walls stabilized by sheathing. The primary stability resistance is provided by translational (lateral) stiffness supplied at the fastener locations to the cold-formed steel studs. This paper separates the source of this translational stiffness into two parts: local and diaphragm. To an...
متن کاملPiecewise Function Hysteretic Model for Cold-Formed Steel Shear Walls with Reinforced End Studs
Cold-formed steel (CFS) shear walls with concrete-filled rectangular steel tube (CFRST) columns as end studs can upgrade the performance of mid-rise CFS structures, such as the vertical bearing capacity, anti-overturning ability, shear strength, and fire resistance properties, thereby enhancing the safety of structures. A theoretical hysteretic model is established according to a previous exper...
متن کاملnon-linear study of various slit shear walls in steel structures
seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...
15 صفحه اولOn Cold-Formed Steel Construction
Powder-actuated (also referred to as low velocity or powder-driven) fasteners are commonly used to attach cold-formed steel framing members, usually a track, to a concrete or structural steel support. Although commonly used, their behavior is less well understood than other fasteners such as screws, bolts and welds. The AISI Cold-Formed Steel Design Manual does not explicitly address powder act...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thin-Walled Structures
سال: 2014
ISSN: 0263-8231
DOI: 10.1016/j.tws.2013.10.023