Design of Roll Bond Evaporator for Room Air Conditioner using Eco-friendly Refrigerant, R-32 (DiFluoroMethane)
نویسندگان
چکیده
منابع مشابه
Design and Experimentation of Roll Bond Evaporator for Room Air Conditioner with R-22 as Refrigerant
The world is looking towards producing products which consume less power without compromising on quality of life. The increase in use of refrigeration and air conditioning appliances are contributing to global warming. The world wide temperatures are shooting up at an increasing rate. This paper presents a design of roll bond evaporator as the heat exchanger to provide cooling in room air condi...
متن کاملSeasonal Applicability of Refrigerant Release Technology in Room Air Conditioner
The refrigerant release technology relieves even eliminates the over-compression loss of scroll compressor by bypassing the refrigerant in the compression chamber to the suction pipe under small system pressure ratio conditions. Because the room air conditioner works in mild conditions at most of the time, its seasonal energy performance is expected to be effectively improved by the refrigerant...
متن کاملApplication of Nonazeotropic Refrigerant Mixtures in Multi-Zone Heat Pump Room Air Conditioner with Hot Water System
متن کامل
Evaluation of a Refrigerant R410A as Substitute for R22 in Window Air-conditioner
CFCs have been phased out, except for essential users, and HCFCs are to be eliminated by 2020, because of their ozone depletion potential. This generates a need for the investigation of zero ozone depletion potential (ODP) refrigerants or refrigerant blends. R410A is among newer brand of refrigerant blends, with zero ODP. The biggest difference to R22 is the pressure levels generated which are ...
متن کاملEffects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance
An experimental investigation was implemented to determine the capacity degradation due to non-uniform refrigerant and air flow distributions, and to assess the potential to recover the lost capacity via controlling refrigerant distribution between individual refrigerant circuits. The tests were performed on a three-circuit, threedepth-row, finned-tube evaporator. Refrigerant inlet quality, exi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Innovative Research in Science, Engineering and Technology
سال: 2016