Design of Pulse Oximeter Solution for Conscious Rodents
نویسندگان
چکیده
منابع مشابه
Design of Pulse Oximeter Simulator Calibration Equipment
Saturation of peripheral oxygen (SpO2) is one of the most important parameters of vital signs. Pulse oximeter which based on near-infrared spectroscopy is commonly used as a non-invasive method to measure SpO2[1] ,Currently, medical device manufacturers as well as metrology measurement agencies in China usually use pulse oximeter simulator as the commonly accepted functional calibration equipme...
متن کاملDesign and Development of Pulse Oximeter
A pulse oximeter is a medical device that indirectly monitors or measure the oxygen saturation of a patient's blood (as opposed to measuring oxygen saturation directly through a blood sample) and changes in blood volume in the skin, producing a photoplethysmogram. The pulse oximeter may be included into a multi parameter patient monitor. This also displays the pulse rate. There are many portabl...
متن کاملA Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملPulse Oximeter Calibrator
........................................................................................................................................................ 5 Table of Figures ............................................................................................................................................ 6 Table of Tables .....................................................................
متن کاملathree-wavelength pulse oximeter for carboxyhemoglobin determination
pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. this paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (hbco), by unfiltered leds at 660 nm, 810 nm, and 940 nm. background information is given on the theory of pulse oximetry. theoretical approximations and calculations w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: UF Journal of Undergraduate Research
سال: 2020
ISSN: 2638-0668
DOI: 10.32473/ufjur.v22i0.121740