Design of Lightning Arresters for Electrical Power Systems Protection
نویسندگان
چکیده
منابع مشابه
Simulation of Lightning Overvoltages in Electrical Power Systems
Lightning strikes to overhead transmission lines cause travelling waves which propagate along the overhead line and enter substations where they cause overvoltages which can pose a risk to any items of equipment connected, such as cables or transformers. With the use of metal-oxide arresters, these overvoltages are reduced to values which, taking into account an adequate safety margin, are belo...
متن کاملAvionics lightning protection design GUI
In order to build aircraft that are lighter and thus, use less fuel, aircraft manufacturers have begun using carbon composite material to fabricate the airframes instead of aluminum. An undesired effect of this change is the increase in severity of the indirect effects of lightning strikes to the airframe on the electrical equipment used on the aircraft (avionics). The more severe lightning tra...
متن کاملLightning Protection of Overhead Power Distribution Lines
Distribution lines are often located in areas with high ground flash densities, being therefore subject to lightning-caused power interruptions. This paper presents an overview of the various types of lightning overvoltages that can arise on overhead power distribution networks, as well as typical voltage waveforms. The effectivenesses of the most important methods for mitigating such overvolta...
متن کاملKnowledge Management and Intelligent Decision Support for Protection Scheme Design and Application in Electrical Power Systems
The paper describes a research project carried out in conjunction with two major UK utilities, focusing on the introduction of knowledge management and intelligent decision support to the existing protection design and application processes operated within both companies. A brief overview is provided of the generic design process, and the development of the web-based Design Engineering Knowledg...
متن کاملLightning Protection of Ehv Substations in Iran
Extra high voltage (EHV) substations are extremely vulnerable to the hazard of lightning strokes therefore, the shielding of these substations with a highly reliable protective scheme (shield wires) is an essential undertaking. In this paper an attempt is made to clarify the design procedure for shielding EHV substations against lightning with special reference to Iran.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Electrical and Electronic Engineering
سال: 2013
ISSN: 1804-3119,1336-1376
DOI: 10.15598/aeee.v11i6.661