Design of Ionization Chamber for CLAPA II

نویسندگان

چکیده

The multi-strip ionization chamber functions as a location and dosage monitor for the Compact LAser Plasma Accelerator II (CLAPA II) beam delivery system, allowing laser pulse diagnostics. properties of planned were studied using Boag’s theory Monte Carlo simulation in this research, energy loss gain 40 MeV–230 MeV proton beams parallel plate simulated by SRIM tools FLUKA program. effects various working gases on are explored, some reference opinions supplied later gas selection. collecting efficiency under deviations was determined theory. findings reveal that when air gap is 7mm bias voltage over 1000V, chamber’s secondary particle collection may reach more than 90%. When intensity 1pA, calculated, detector’s output current order 6 nA.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and fabrication of cylindrical ionization chamber for application in radiation protection

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

متن کامل

Electrical Design Considerations for a 40mhz Gas Ionization Chamber*

The front IR quadrupole absorbers (TAS) and the IR neutral particle absorbers (TAN) in the high luminosity insertions of the Large Hadron Collider (LHC) each absorb approximately 1.8 TeV of forward collision products on average per pp interaction (~235W at design luminosity 10cms). This secondary particle flux can be exploited to provide a useful storage ring operations tool for optimization of...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advances in transdisciplinary engineering

سال: 2022

ISSN: ['2352-751X', '2352-7528']

DOI: https://doi.org/10.3233/atde221167