Design of Flat-Plate Dehumidifiers for Humidification–Dehumidification Desalination Systems
نویسندگان
چکیده
منابع مشابه
Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran
This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of ...
متن کاملInnovative wick design for multi-source, flat plate heat pipes
We present a novel micro-heat pipe wick design and fabrication technique to significantly boost the effective thermal conductivity of the heat pipe relative to the monolithic substrate material. Extensive porous flow modeling of the process has provided critical information on the key parameters and the resulting anisotropic wick designs have shown robust performance improvements. A methanol ch...
متن کاملStability Analysis for Wake Flow Behind a Flat Plate
Neutral stability limits for wake flow behind a flat plate is studied using spectral method. First, Orr-Sommerfeld equation was changed to matrix form, covering the whole domain of solution. Next, each term of matrix was expanded using Chebyshev expansion series, a series very much equivalent to the Fourier cosine series. A group of functions and conditions are applied to start and end points i...
متن کاملinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Stability Analysis for Wake Flow Behind a Flat Plate
Neutral stability limits for wake flow behind a flat plate is studied using spectral method. First, Orr-Sommerfeld equation was changed to matrix form, covering the whole domain of solution. Next, each term of matrix was expanded using Chebyshev expansion series, a series very much equivalent to the Fourier cosine series. A group of functions and conditions are applied to start and end points i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Heat Transfer Engineering
سال: 2013
ISSN: 0145-7632,1521-0537
DOI: 10.1080/01457632.2013.730355