Design of Active-Type Personal Dosemeter for High-Energy Neutrons
نویسندگان
چکیده
منابع مشابه
Design of Active-Type Personal Dosemeter for High-Energy Neutrons
In order to design an active-type personal dosemeter having sufficient sensitivity to high-energy neutrons up to 100 MeV, the characteristic response of several types of silicon (Si) semiconductor detectors has been investigated experimentally and theoretically. At first, the response of each detector has been checked to protons accelerated by a Van de Graff accelerator installed at Kobe Univer...
متن کاملActive electronic personal dosemeter in interventional radiology.
A recently developed active electronic personal dosemeter (AEPD) was utilised in order to measure the levels and the structure of occupational exposure to scattered X-ray radiation of medical staff who performed percutaneous revascularisation therapy that involves interventional radiology (IR) on the pelvis and upper leg arteries. The AEPDs, placed on the operators' and assistants' chests, that...
متن کاملEnergy response for high-energy neutrons of multi-functional
We have developed a small, light, and multi-functional electronic personal dosimeter (EPD) using four semiconductor radiation detectors for dose monitoring of workers at nuclear power plants and high-energy accelerator facilities. This dosimeter is about 103 x 55 x 15 mm in size and approximately 110 g in weight, and capable of measuring gamma-ray and neutron doses in Hp(10), and beta-ray dose ...
متن کاملPersonal dosimetry in a mixed field of high-energy muons and neutrons.
High energy accelerators quite often emit muons. These particles behave in matter as would heavy electrons and are thus difficult to attenuate with shielding in many situations. Hence, these muons can be a source of radiation exposure to personnel and suitable methods of measuring the absorbed dose received by these people is obviously required. In practical situations: such muon radiation fiel...
متن کاملA TLD-based personal dosemeter system for aircrew monitoring.
Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is assessed by the Extended Pair method calibrated in the CERN-EU High-Energy Refere...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Progress in Nuclear Science and Technology
سال: 2011
ISSN: 2185-4823
DOI: 10.15669/pnst.1.158