Design Modification of Klandasan Parking Building Using Flat Slab with Drop Panel And Shear Wall Method
نویسندگان
چکیده
The Klandasan Parking Building (GPK) is an 8-story parking built in Balikpapan that serves as vehicle and uses a conventional structure system (columns, beams, plates) where the highest beam about 800 mm. To maximize clearance of each story, alternative planned by removing beams called flat slabs. new plan conducted modifying into dual which consists Intermediate Moment Resisting Frame, plate with drop panels used to withstand gravitational loads on buildings Structural Wall System (SWS) installed resist lateral such earthquake wind. Structure’s refers SNI 03-2847-2013 03-1726-2012 are Indonesia’s concrete codes respectively. In addition, PPURG 1987 also determine for building. analysis result shows building could be changed from 8 9 stories using same total height stories. depth plates supported interior exterior columns 250 mm 100 Turning shear wall, thickness 350 can loads.
منابع مشابه
Strain based panel elements for shear wall analysis
The finite element method (FEM) can be applied to practically analyze the tall buildings in which the shear walls are used to resist the lateral loads. Accordingly, a variety of displacement and strain-based as well as frame macro elements have been proposed for analysis of the tall buildings. With respect to application of the lower order plane stress elements, analytical problems may arise wi...
متن کاملchemical recycling of polycarbonate waste using conventional heating and microwave assisted method
پلی کربنات یکی از پلاستیکهای مهمی است که به صورت گسترده در تولید لوحهای فشرده، قطعات رایانه، مواد ساختمانی و غیره مورد استفاده قرار می گیرد. این پلیمر بصورت عمده از تراکم مونومر بیس فنولa (bpa) و کربنیل کلرید یا دی متیل کربنات ها بدست می آید. در سالهای اخیر بازیافت شیمیایی پلی کربنات بیشتر مورد توجه بوده است. بازیافت شیمیایی پلی کربنات برای بدست آوردن مواد اولیه آن با روشهای متفاوتی مانند تجزی...
Comparison of plasticity and stiffness of steel shear walls with composite steel plate shear wall
The steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. Composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...
متن کاملbuckling of viscoelastic composite plates using the finite strip method
در سال های اخیر، تقاضای استفاده از تئوری خطی ویسکوالاستیسیته بیشتر شده است. با افزایش استفاده از کامپوزیت های پیشرفته در صنایع هوایی و همچنین استفاده روزافزون از مواد پلیمری، اهمیت روش های دقیق طراحی و تحلیل چنین ساختارهایی بیشتر شده است. این مواد جدید از خودشان رفتارهای مکانیکی ارائه می دهند که با تئوری های الاستیسیته و ویسکوزیته، نمی توان آن ها را توصیف کرد. این مواد، خواص ویسکوالاستیک دارند....
Finite Element Method for Static Cyclic Behavior of Steel Shear Wall with Corrugated Plates
The system of steel shear wall is an initiative resistance system against the lateral load such as an earthquake and the wind that has been researched in the last three decades. Currently, this system is noticed more than other systems because of adequate stiffness, ductility, and more energy absorption. The system of steel shear wall with corrugated sheets has been offered as an innovative sys...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Specta
سال: 2023
ISSN: ['2549-2713', '2622-9099']
DOI: https://doi.org/10.35718/specta.v7i1.66