Design aspects of a MSE diagnostic for ITER
نویسندگان
چکیده
منابع مشابه
investigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
diagnostic and developmental potentials of dynamic assessment for writing skill
این پایان نامه بدنبال بررسی کاربرد ارزیابی مستمر در یک محیط یادگیری زبان دوم از طریق طرح چهار سوال تحقیق زیر بود: (1) درک توانایی های فراگیران زمانیکه که از طریق برآورد عملکرد مستقل آنها امکان پذیر نباشد اما در طول جلسات ارزیابی مستمر مشخص شوند; (2) امکان تقویت توانایی های فراگیران از طریق ارزیابی مستمر; (3) سودمندی ارزیابی مستمر در هدایت آموزش فردی به سمتی که به منطقه ی تقریبی رشد افراد حساس ا...
15 صفحه اولDivertor interferometer diagnostic for ITER
In the harsh environment of the divertor region in ITER, plasmas spanning a huge density range from 1019 to 1022 m−3 are anticipated making measurement of the electron density particularly challenging. For any reasonable wavelength choice, the total phase measured by a conventional two-color interferometer system is always 2 and therefore subject to fringe counting errors. This problem can be r...
متن کاملThe Design and Implementation of Diagnostic Systems on ITER*
In order to meet the expected needs for first wall and plasma measurements, ITER will require about 40 different diagnostic systems drawn from all the main generic diagnostic groups – magnetics, neutron systems, optical and microwave systems, spectroscopic, bolometric, probes, pressure gauges and gas analysers. The design and implementation of the diagnostic systems is a major challenge because...
متن کاملDesign of the ITER high-frequency magnetic diagnostic coils
This paper is an overview of work carried out on the design of the ITER high-frequency magnetic diagnostic coil (HF sensor). In the first part, the ITER requirements for the HF sensor are presented. In the second part, the ITER reference design of the HF sensor has been assessed and showed some potential weaknesses, which led us to the conclusion that alternative designs could usefully be exami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2004
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.1787604