Design and Validation of Plate Earthing System for Equipment Earthing

نویسندگان

چکیده

Earthing system is an essential part of electrical installation as it helps in eliminating shock hazards and also provide zero voltage reference point for the equipment. Design earthing involves, measurement soil resistivity proposed site electrode & determining conductor type required number earth electrodes order to achieve resistance value. This paper describes methodology followed design validation a plate equipment new test laboratory, which had requirement less than 1 Ohm mandated by supplier. will be helpful personnel involved system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HV Substation Earthing Design for Mines

-High Voltage (HV) substation forms important assets for the mining industries. The existences of these substations necessitate earthing design to ensure safety compliance to the mine regulations. The HV system within the mines is consisted of multiple substations which are connected throughout and underground cable. These substations provide the load with the required electrical power to perfo...

متن کامل

Earthing Techniques

1.3 MAKING A MEASUREMENT ........................................................................................................................................... 1.3.1 PRINCIPLES...............................................................................................................................................................4 1.3.2 SOIL RESISTIVITY TESTING PROCEDURE GUIDELINES ......

متن کامل

Design of Earthing System for a Substation : A Case Study

This paper presents the design of earthing system for 132 KV substation and simulation for calculation of required parameters. This paper is to provide information pertinent to safe earthing practices in ac substation design and to establish the safe limits of potential difference under normal and fault conditions. The grounding grid system of a practical 220 kV substation is calculated by MATL...

متن کامل

The neuromodulative role of earthing.

Neuromodulation is a process of inhibition, stimulation, modification and regulation or therapeutic alteration of activity, electrically and chemically in the peripheral, central or autonomic nervous systems. Direct electric current or electric field alternates the function of nervous system. Coupling the human organism with the Earth directly or via a wire conductor changes the electric potent...

متن کامل

simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of CPRI

سال: 2023

ISSN: ['0973-0338']

DOI: https://doi.org/10.33686/pwj.v19i1.1118