Design and Performance Analysis of Grid Connected Photovoltaic (GCPV) based DSTATCOM for Power Quality Improvements
نویسندگان
چکیده
منابع مشابه
application of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولModeling of Photovoltaic Grid Connected Inverters Based on Nonlinear System Identification for Power Quality Analysis
Photovoltaic systems are attractive renewable energy sources for Thailand because of high daily solar irradiation, about 18 MJ/m2/day. Furthermore, renewable energy is boosted by the government incentive on adders on electricity from renewable energy like solar PV, wind and biomass, introduced in the second half of 2000s. For PV systems, domestic rooftop PV units, commercial rooftop PV units an...
متن کاملPower Quality Improvement for Grid Connected Photovoltaic System
This paper proposes a single-phase five-level photovoltaic (PV) inverter topology for grid-connected PV systems with a novel pulse width-modulated (PWM) control scheme. Two reference signals identical to each other with an offset equivalent to the amplitude of the triangular carrier signal were used to generate PWM signals for the switches. A digital proportional–integral current control algori...
متن کاملPower Quality Analysis of Power System Involving Grid Connected Photovoltaic (PV) System
Power Quality is an essential aspect for reliable operation of power grid including Photovoltaic based generation. This paper focuses on real time problem of injection of harmonics and resonance into power network having 5MW solar plant. The solar plant includes 10 inverters each of 500KW connected to 33kV bus. Power produced by plant is explored via 4km cable at 220kV, where conventional plant...
متن کاملControl System Design and Fault-Ride-through Performance Analysis of Grid-Connected Microturbine Generation System
In recent years, microturbines as one the distributed generation sources have widly used. This paper investigates the control structure of the microturbine and analyzes its performance in grid-connected mode. In this way, first, the mechanical model of the microturbine is presented. Then, the electrical structure of the microturbine, consisting of permanent magnet synchronous generator (PMSG) ...