Design and Implementation of PS-ZVS Full Bridge Converter

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New ZVS-PWM Full-Bridge Converter

A full-bridge converter which employs a coupled inductor to achieve zero-voltage switching of the primary switches in the entire line and load range is described. Because the coupled inductor does not appear as a series inductance in the load current path, it does not cause a loss of duty cycle or severe voltage ringing across the output rectifier. The operation and performance of the proposed ...

متن کامل

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between t...

متن کامل

Cree Silicon Carbide Power White Paper: Highly Efficient, and Compact ZVS Resonant Full Bridge Converter Using 1200V SiC MOSFETs

Rev. Abstract The most recent version (C2MTM) of Silicon Carbide (SiC) devices is used in a Zero Voltage Switching (ZVS) converter application. A 1200V, 160mohm SiC MOSFET from Cree Inc. is used to design a high-frequency ZVS LLC resonant fullbridge (FB) DC/DC converter. With the outstanding advantages of SiC MOSFET, which has lower junction capacitance and low-on-state resistor compared to a s...

متن کامل

A Zvs Full Bridge Resonant Inverter Based High Step down Multiple Output Converter with Wide Input Voltage Range

DC-BUS based power distribution systems with battery backup have been widely used in aerospace and telecommunication applications, where the bus voltage is usually determined by the battery. In these systems, there are many loads that need different and low operating voltages. Since the bus voltage is usually much higher than the load voltage and varies in a wide range with the stage of charge ...

متن کامل

Analysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype

One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Sciences

سال: 2014

ISSN: 1812-5654

DOI: 10.3923/jas.2014.1588.1593