Design and Development of a Small Gamma Camera Using Coded Apertures and Gamma-ray Semiconductor Detectors
نویسندگان
چکیده
منابع مشابه
Charge transport in arrays of semiconductor gamma-ray detectors.
We analyze the effects of electrode size on performance of arrays of semiconductor gamma-ray detectors, especially when there is significant charge trapping. With large electrodes, motions of holes and electrons are of equal importance, but when the positive electrode is segmented into an array of small elements the contributions of holes to the output, and hence the effects of hole trapping, a...
متن کاملScanner for gamma-ray detectors
The core principle of segmented detectors like AGATA [1], GRETA [2], that will be used in future for 4π gamma detection arrays, is the application of the concept of pulse shape analysis (PSA). The key ingredient for this analysis is a data base containing pulses for all the interaction points inside the segmented detector. A full 3D scanning of the detectors, which experimentally determines pul...
متن کاملFormation interface detection using Gamma Ray log: A novel approach
There are two methods for identifying formation interface in oil wells: core analysis, which is a precise approach but costly and time consuming, and well logs analysis, which petrophysists perform, which is subjective and not completely reliable. In this paper, a novel coupled method was proposed to detect the formation interfaces using GR logs. Second approximation level (a2) of GR log gained...
متن کاملA Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region
Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...
متن کاملGamma-ray spectral imaging using a single-shutter radiation camera
As part of a program to develop mobile robots for reactor environments, we are developing a radiation-imaging camera capable of operating in medium-intensity ( < 2 R/h), medium-energy ( < 8 MeV) gamma-ray fields . A systematic study of available detectors indicated the advisability of a high-Z scintillator. The raster-scanning camera uses a lead-shielded bismuth germanate (BGO) scmtillator (1 ....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Society of Instrument and Control Engineers
سال: 2007
ISSN: 0453-4654
DOI: 10.9746/ve.sicetr1965.43.774