Design and construction of ionization chamber detector for radio-gas chromatography

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A surface ionization detector for capillary gas chromatography.

A novel surface ionization detector using a reducing quartz liner and a Mo emitter with a quartz enclosed internal heater for selective measurement of alkylamines by gas chromatography is designed and evaluated.

متن کامل

Electrical Design Considerations for a 40mhz Gas Ionization Chamber*

The front IR quadrupole absorbers (TAS) and the IR neutral particle absorbers (TAN) in the high luminosity insertions of the Large Hadron Collider (LHC) each absorb approximately 1.8 TeV of forward collision products on average per pp interaction (~235W at design luminosity 10cms). This secondary particle flux can be exploited to provide a useful storage ring operations tool for optimization of...

متن کامل

Design and fabrication of cylindrical ionization chamber for application in radiation protection

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

متن کامل

Ionization Chamber Detector for X-ray with Beam Position Monitoring

Ionization Chambers have been commonly used at beamlines in many synchrotron radiation facilities. Typical ADC ion chambers are pictured in Figure 1. The chambers generate a current proportional to the incident X-ray beam intensity. The ionization chamber allows users to determine the change in beam position in a single axis by comparing two signals that are created as the beam passes through t...

متن کامل

Acoustic flame detector for gas chromatography.

A novel gas chromatography detector is described that uses acoustic signals from a partly premixed hydrogen-air flame burning on top of a capillary. The device, referred to as the acoustic flame detector (AFD), is based on the measurement of the frequency of acoustic transients generated at the burner under a range of operating conditions. The presence of trace amounts of analyte in the flame w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1973

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.22.837