Design and Analysis of tool for fractured abutment screw removal from the dental implant body

نویسندگان

چکیده

Abstract Implant-based restoration is currently seen to be a more reliable option with higher success rates. Biological and technological problems, on the other hand, are common. An implant insertion complication well known many loosening of abutment screw. Fractures implant-abutment may cause fail function efficiently as they leave fragment inside implant. This study aimed introduce modified design tool extract stripped screw from body analyses deformation, stress strain acting using finite element method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill ...

متن کامل

Removal of a fractured locator abutment screw fragment.

BACKGROUND Although, dental implants have been a predictable option to support several types of restorations, mechanical problems are not uncommon. Retaining and abutment screw loosenings/fractures are one of the most common technical problems. AIM To present a step-by-step technique in order to remove a broken locater abutment screw fragment. MATERIALS AND METHODS A 56-year-old, edentulous...

متن کامل

A Simple and Cost Effective Method used for Removal of a Fractured Implant Abutment Screw: A Case Report.

The success of dental implants is based primarily on the extent of osseointegration. The failure of dental implants is not only due to biological factors, such as unsuccessful osseointegration or the presence of peri-implantitis, but may also result from technical complications. Fracture of the implant abutment screw can be a serious problem, as the fragment remaining inside the implant may pre...

متن کامل

A technique for salvaging an implant-supported crown with a fractured abutment screw.

Abutment screw fracture, although uncommon, occurs in clinical practice (Fig. 1,A). In most circumstances, the fractured end can be retrieved and replaced by a new abutment screw. However, sometimes the screw cannot be removed conservatively. By using rotary instruments, internal threads of the screw hole may be damaged and the implant rendered useless. To overcome these problems, this article ...

متن کامل

Management of a malpositioned implant using custom abutment and screw-retained fixed dental prosthesis.

A 32-year-old woman with missing permanent mandibular right molars and left first molar presented for treatment. One of the implants were misaligned during the placement due to sudden mouth closure of the patient. All implants success fully osseointegrated. However, the misaligned implant resulted in substantial mechanical and esthetic restorative challenges. The prosthodontic treatment include...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP conference series

سال: 2022

ISSN: ['1757-899X', '1757-8981']

DOI: https://doi.org/10.1088/1757-899x/1259/1/012027