Deriving an Indoor Environmental Index for Portuguese Office Buildings
نویسندگان
چکیده
منابع مشابه
Deriving an Indoor Environmental Index for Portuguese Office Buildings
In 2002, the European Commission (EU) issued a Directive aiming to reduce the energy consumption of buildings, which was adopted by the EU member states and came into force in 2006. Portugal adopted it by issuing law decrees in 2006 which considered not only the energy saving aspects but also additional specific measures aiming to protect indoor air quality (IAQ). This new legislation is now be...
متن کاملInvestigating the Effects of Environmental Factors on Office Buildings’ Indoor Environment Quality in Iran’s Cold Climate (Case study: Kermanshah)
The inappropriate indoor environmental quality of a building causes different problems such asheadache and breathing difficulties which are called the syndrome of building sickness. These diseases reduce the efficiency of people and deteriorate the quality of their life. Studies carried out in hundreds of big office buildings across the world show that the indoor environment qualities of these ...
متن کاملAir Quality and Thermal Comfort in Office Buildings: Results of a Large Indoor Environmental Quality Survey
This paper presents results of over 34,000 survey responses to air quality and thermal comfort questions in 215 buildings in US, Canada, and Finland. Results show that 80% or more of the occupants expressed satisfaction with their thermal comfort in only 11% of the buildings surveyed. Air quality scores were somewhat higher, with 26% of buildings having 80% or occupant satisfaction. With respec...
متن کاملIndoor environmental quality in six commercial office buildings in the midwest United States.
The aims of this study were to characterize physical, mechanical, and environmental factors influencing indoor environmental quality (IEQ) in commercial office buildings; document occupant perceptions and psychosocial attributes; and evaluate relationships among these parameters. Six large office buildings in metropolitan areas were selected in Iowa, Minnesota, and Nebraska. Comprehensive sampl...
متن کاملIndoor Air Quality of Office Buildings in the Helsinki Area
Indoor air quality (IAQ) was investigated in 19 open-plan offices and 30 office rooms in order to compare the differences in these two different types of office environments. No moisture or mold problems had been reported from the present buildings, but the employees had complained about the IAQ. The results revealed only slight differences in the IAQ of the two different types of office enviro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Technologies
سال: 2016
ISSN: 2227-7080