Depth Resolution of Electron Spectroscopy Analysis
نویسندگان
چکیده
منابع مشابه
Determination of the electron escape depth for NEXAFS spectroscopy.
A novel method was developed to determine carbon atom density as a function of depth by analyzing the postedge signal in near-edge X-ray absorption fine structure (NEXAFS) spectra. We show that the common assumption in the analysis of NEXAFS data from polymer films, namely, that the carbon atom density is constant as a function of depth, is not valid. This analysis method is then used to calcul...
متن کاملHigh resolution two-dimensional optical spectroscopy of electron spins
M. Salewski, S. V. Poltavtsev, 2 I. A. Yugova, G. Karczewski, M. Wiater, T. Wojtowicz, 4 D. R. Yakovlev, 5 I. A. Akimov, 5 T. Meier, and M. Bayer 5 Experimentelle Physik 2, Technische Universität Dortmund, 44221 Dortmund, Germany Spin Optics Laboratory, St. Petersburg State University, St. Petersburg 198504, Russia Institute of Physics, Polish Academy of Sciences, PL-02668 Warsaw, Poland Intern...
متن کاملData processing for atomic resolution electron energy loss spectroscopy.
The high beam current and subangstrom resolution of aberration-corrected scanning transmission electron microscopes has enabled electron energy loss spectroscopy (EELS) mapping with atomic resolution. These spectral maps are often dose limited and spatially oversampled, leading to low counts/channel and are thus highly sensitive to errors in background estimation. However, by taking advantage o...
متن کاملHigh-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.
An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability...
متن کاملHIGH RESOLUTION LASER SPECTROSCOPY IN COLD SUPERSONIC MOLECULAR BEAMS COOLING, REDUCTION OF DOPPLER WIDTH AND APPLICATION
The cooling of molecules during the adiabatic expansion of supersonic seeded molecular beams is reviewed and illustrated by the example of NO -molecules. The reduction of the Doppler width by collimation of the beam and the cooling to low rotational temperatures brings a significant simplification of the complex NO -absorption spectrum and allows its assignment. The measured rotational tem...