Dental unit water lines decontamination with the aid of nanotechnology
نویسندگان
چکیده
منابع مشابه
Evaluation of Bacterial Contamination in Dental Unit Water Lines in Zahedan in 2016-2017
Background & Aim: Due to a constant contact of dentists and patients with water and aerosols generated from the dental units, the quality of dental unit waters is very important. This study aimed to evaluate bacterial contamination of dental unit water lines in Zahedan in 2016-2017. Methods: In this descriptive analytical study, 2304 water samples from four parts of unit including cup filler, ...
متن کاملMolecular analysis for bacterial contamination in dental unit water lines.
Bacterial contamination in dental unit waterlines (DUWLs) was evaluated by molecular techniques in addition to the conventional culture method. Water samples (n=8) from DUWLs were investigated for heterotrophic bacteria by culture method using R2A agar. The selected bacterial antibiotic-resistance genes and Legionella species-specific 16SrDNA were identified by PCR. The profiles of bacterial co...
متن کاملevaluation of ozone application in dental unit water lines con¬taminated with pathogenic acanthamoeba
background: in this study morphological and molecular characterization of acanthamoeba strains, isolated from dental unit waterlines (duwls) were surveyed and the levels of disinfection achievable in vitro by the application of ozone disinfectant to duwls were evaluate. methods: water samples were collected from air-water syringes, cup fillers and tap water before and at the end of the workin...
متن کاملEvaluation of Ozone Application in Dental Unit Water Lines Contaminated with Pathogenic Acanthamoeba
BACKGROUND In this study morphological and molecular characterization of Acanthamoeba strains, isolated from dental unit waterlines (DUWLs) were surveyed and the levels of disinfection achievable in vitro by the application of ozone disinfectant to DUWLs were evaluate. METHODS Water samples were collected from air-water syringes, cup fillers and tap water before and at the end of the working ...
متن کاملEvaluation of the PotoClean® decontamination technology for reprocessing of water supply lines in dental units during routine work
BACKGROUND A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. METHOD The efficacy of a reg...