Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology
نویسندگان
چکیده
منابع مشابه
Low-Energy Plasma Focus Device as an Electron Beam Source
A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line ...
متن کاملOn the source of plasma density and electric field perturbations in PMSE and PMWE regions
تشکیل ابرهای مسسفری در فصل تابستان و در ارتفاع ۸۰ تا ۹۰ کیلومتری از سطح زمین در نواحی قطبی دارای اهمیت بسیار زیادی می باشند. ارتباط مستقیم بین افزایش مشاهده این ابرها و پدیده گرم شدن کره زمین از دلایل اصلی اهمیت مطالعه این ناحیه می باشد. طبق تحقیقات انجام شده افزایش گازهای گلخانه ای باعث کاهش دما در این ناحیه از جو می شود. از طرف دیگر افزایش گاز متان و فرایند تجزیه آن توسط نور خورشید نیز باعث ا...
متن کاملSmall plasma focus as neutron pulsed source for nuclides identification.
In this paper, we present preliminary results on the feasibility of employing a low energy (2 kJ, 31 kV) plasma focus device as a portable source of pulsed neutron beams (2.45 MeV) generated by nuclear fusion reactions D-D, for the "in situ" analysis of substances by nuclear activation. This source has the relevant advantage of being pulsed at requirement, transportable, not permanently radioac...
متن کاملMagnetically Induced Plasma Rotation and the Dense Plasma Focus
für Naturforschung in cooperation with the Max Planck Society for the Advancement of Science under a Creative Commons Attribution 4.0 International License. Dieses Werk wurde im Jahr 2013 vom Verlag Zeitschrift für Naturforschung in Zusammenarbeit mit der Max-Planck-Gesellschaft zur Förderung der Wissenschaften e.V. digitalisiert und unter folgender Lizenz veröffentlicht: Creative Commons Namen...
متن کاملMeter Scale Plasma Source For Plasma Wakefield Experiments
High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2015
ISSN: 1742-6596
DOI: 10.1088/1742-6596/591/1/012021