Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
نویسندگان
چکیده
منابع مشابه
Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
BACKGROUND Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported. CASE PRESENTATION This is a retrospective review of clinical presentations, ra...
متن کاملDelayed Orbital Hemorrhage around Alloplastic Implants after Blowout Fracture Reduction
Alloplastic implants have been used to repair orbital wall fractures in most cases. Orbital hemorrhage is a rare complication of these implants and has been reported rarely in Korea. The purpose of this article is to report a late complication case focusing on their etiology and management. A 20-year-old male patient underwent open reduction with Medpor (porous polyethylene) insertion for bilat...
متن کاملOrbital cellulitis: a rare complication after orbital blowout fracture.
PURPOSE To report the incidence of orbital cellulitis after orbital blowout fracture. DESIGN Retrospective, noncomparative, interventional case series. PARTICIPANTS All patients with orbital cellulitis and a history of recent orbital fracture. METHODS A medical record review of clinical history, imaging studies, and surgical and treatment outcome was performed. MAIN OUTCOME MEASURES Res...
متن کاملA Case of Orbital Abscess following Porous Orbital Implant Infection
PURPOSE We present a case of orbital abscess following porous orbital implant infection in a 73-year-old woman with rheumatoid arthritis. METHODS Just one month after a seemingly uncomplicated enucleation and porous polyethylene (Medpor) orbital implant surgery, implant exposure developed with profuse pus discharge. The patient was unresponsive to implant removal and MRI confirmed the presenc...
متن کاملIsolated Medial Orbital Wall Blowout Fracture
Figure 1. Coronal view of computed tomography max/face revealing a right-sided medial orbital wall blowout fracture without entrapment.