Delayed Foreign-body Reaction to Absorbable Implants in Metacarpal Fracture Treatment

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Foreign-Body Granuloma after Metacarpal Fracture Treatment with Absorbable Implants

The treatment of unstable fractures or complex injuries of the hand frequently requires the implementation of rigid internal fixation. Traditionally, metallic implants have been used to achieve stability. However, the complication rates of metallic implants are high, with major complications reported in 36% of the patients considered in a series [1]. These complications included nonunion, delay...

متن کامل

Osteolytic changes accompanying degradation of absorbable fracture fixation implants.

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels...

متن کامل

Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers.

Biodegradable rods of polyglycolide or lactide-glycolide copolymer were used in the internal fixation of a variety of fractures and osteotomies in 516 patients. A clinically manifest foreign-body reaction occurred in 41 patients (7.9%), producing a fluctuant swelling at the implantation site after an average of 12 weeks. Spontaneous sinus formation or surgical drainage yielded a sterile exudate...

متن کامل

Foreign Body Response to Subcutaneous Implants in Diabetic Rats

Implantation of synthetic matrices and biomedical devices in diabetic individuals has become a common procedure to repair and/or replace biological tissues. However, an adverse foreign body reaction that invariably occurs adjacent to implant devices impairing their function is poorly characterized in the diabetic environment. We investigated the influence of this condition on the abnormal tissu...

متن کامل

[Delayed foreign body reaction to steel wire suture resembling basal cell carcinoma].

encia en estas razas es desconocida, pero se considera ustancialmente inferior a la de la raza negra4,5,7,8. La patogenia de la pigmentación de las papilas funiformes es desconocida. Werchniack et al9, a partir de a presencia de pigmentación de las papilas fungiformes n madre e hija sugieren una herencia autosómica domiante que no ha sido previamente descrita ni corroborada or otros artículos. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Orthopaedics & Related Research

سال: 2010

ISSN: 0009-921X

DOI: 10.1007/s11999-010-1388-3