Delamination of Abluminal Polymer of Biolimus-Eluting Stent
نویسندگان
چکیده
منابع مشابه
Delamination of abluminal polymer of biolimus-eluting stent.
Manuscript received August 10, 2011; accepted September 3, 2011. Corporation, Tokyo, Japan) with abluminal biodegradable polymer in the mid-RCA was attempted. It passed through the everolimus-eluting stent in the proximal RCA without difficulty. However, it would not advance to the target lesion in the mid-RCA (Fig. 1C). Additional balloon inflation was performed. A 12-mm Driver Sprint stent (M...
متن کاملThe twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.
INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compar...
متن کاملThe three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
AIMS The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). METHODS AND RESULTS One thousand seven hundred and seven patients were randomised to unrestricted...
متن کاملClinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 pat...
متن کاملBiolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction.
OBJECTIVE To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS The LEADERS trial is a multicentre all-comer study, where patients (n=170...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Interventions
سال: 2012
ISSN: 1936-8798
DOI: 10.1016/j.jcin.2011.09.028