Defibrillation failure with an electrical short circuit caused by internal insulation breach
نویسندگان
چکیده
منابع مشابه
Shock-induced right ventricular pacing failure caused by a short circuit: Uncommon but life-threatening complication of the Riata lead
Introduction The Riata and Riata ST implantable cardioverter-defibrillator (ICD) leads, a narrow caliber silicone lead without an outer jacket, have been shown to be prone to structural and electrical failure. While much interest has been shown in potentially lethal high-voltage (HV) failures caused by electrical short circuits due to a breach in the ethylene tetrafluoroethylene (ETFE) insulati...
متن کاملMechanisms of Defibrillation Failure
Since defibrillation by high-energy electric shocks is the only effective means for termination of ventricular fibrillation, defibrillation shocks are now widely used in clinical practice for prevention of sudden cardiac death. However, the high-energy shocks could result in myocardial dysfunction and damage (Runsio et al., 1997) and in psychological trauma (Maisel, 2006). Comprehensive underst...
متن کاملA failure of internal jugular vein catheterization caused by the internal jugular vein occlusion
provided the original work is properly cited. CC Central venous catheterization is frequently used as the procedure for preparation of major surgery, chemotherapy, total parenteral nutrition, and etc [1]. Usually, the catheterization sites are femoral vein, subclavian vein, and internal jugular vein (IJV). Because the right IJV has easy accessibility, and it gives direct route for right atrium ...
متن کاملBreast calcifications following electrical defibrillation: An unusual mammographic appearance
We present a case of a 57-year-old woman with a past medical history of end-stage renal disease and a recent history of electrical defibrillation who arrived for her annual mammogram with no breast-related complaints. The mammogram showed interval development of unusual clusters of heterogeneous calcifications. The patient underwent stereotactic core-needle biopsy for definitive diagnosis. The ...
متن کاملOptimal parameters of electrical impulses for defibrillation by condenser discharges.
• Determination of the defibrillation threshold of the heart is important not only for developing the technique of defibrillation per se but also for improving the design of instruments used for that purpose. Previous workhas shown the necessity of selecting, for the discharge circuit, parameters that will keep voltage as low as possible, but many questions concerning the optimal parameters for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: HeartRhythm Case Reports
سال: 2021
ISSN: 2214-0271
DOI: 10.1016/j.hrcr.2021.04.009