Defect depth estimation using magneto optical imaging with magnetophotonic crystal
نویسندگان
چکیده
منابع مشابه
Magneto-Optical properties of GaP single crystal
The temperature dependence of magneto-optical and magneto-photoconductivity measurements were carried out in the range of (200-330) K. A home made optical cryostat was used for the measurements. The measured room temperature value of the energy gap was found to be 2.211 eV. The temperature coefficient of energy gap was found to be -5.48×10-4 eV/K obtained by the optical absorption method and -4...
متن کاملEnhancement of the Magneto-Optical Kerr Effect in One- Dimensional Magnetophotonic Crystals with Adjustable Spatial Configuration
We studied magnetophotonic crystals (MPCs) with introduced magneticdefect layer sandwiched between magnetic and dielectric Bragg mirrors. Thesemagnetophotonic crystals have excellent capabilities to enhance reflection and Kerrrotation simultaneously. By adjusting spatial configuration such as repetition numbersof Bragg mirrors and thickness of magnetic defect layer, we a...
متن کاملMicroscopic Magnetic Study of Ordinary Chondrite Using Magneto-optical Imaging
Fe-Ni alloys, which are kamacite (<10 wt% Ni), taenite (30 ~ 40 wt % Ni), and tetrataenite (ordered Fe 50 Ni 50), are the dominant magnetic minerals in the metamorphic (type 5-6) ordinary chondrites [1], and the carrier of the remanent magnetization is high coercivity tetrataenite [1,2,3]. Metallographic studies reported that there are two types of Fe-Ni grains in the metamor-phic ordinary chon...
متن کاملDefect Depth Estimation Using Neuro-Fuzzy System in TNDE
Abstract: Recently, supervised artificial neural networks have obtained success to reveal and provide quantitative information concerning defects in TNDE (Thermographic NonDestructive Evaluation). Supervised neural networks may converge to local minimum and their training procedure are usually long. In this study, a neuro-fuzzy approach is applied to characterize subsurface defects in TNDE. Sim...
متن کاملScanning tunneling microscope for magneto-optical imaging
• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Magnetics Society of Japan
سال: 2015
ISSN: 1882-2924,1882-2932
DOI: 10.3379/msjmag.1508r008