Deep Red Emissive Carbonized Polymer Dots with Unprecedented Narrow Full Width at Half Maximum
نویسندگان
چکیده
Adv. Mater. 2020, 32, 1906641 In the originally published version of this article, data for histological evaluation CPDs toxicity in brain at CON-7d was duplicated Figure S18, instead correct image CPDs-1d being used. The figure is hereby corrected. authors apologize mistake and any inconvenience caused.
منابع مشابه
A 14-ps full width at half maximum high-speed photoconductor fabricated with intersecting InP nanowires on an amorphous surface
We demonstrate a high-speed polarization-insensitive photoconductor based on intersecting InP nanowires synthesized between a pair of hydrogenated silicon electrodes deposited on amorphous SiO2 surfaces prepared on silicon substrates. A 14-ps full width at half maximum de-embedded impulse response is measured, which is the fastest reported response for a photodetector fabricated using nanowires...
متن کاملFluorescent/phosphorescent dual-emissive conjugated polymer dots for hypoxia bioimaging.
A kind of fluorescent/phosphorescent dual-emissive conjugated polyelectrolyte has been prepared by introducing phosphorescent platinum(ii) porphyrin (O2-sensitive) into a fluorene-based conjugated polyelectrolyte (O2-insensitive), which can form ultrasmall conjugated polymer dots (FP-Pdots) in the phosphate buffer solution (PBS) via self-assembly caused by their amphiphilic structures with hydr...
متن کاملEmission wavelength tuning of fluorescence by fine structural control of optical metamaterials with Fano resonance
We demonstrated fine emission wavelength tuning of quantum dot (QD) fluorescence by fine structural control of optical metamaterials with Fano resonance. An asymmetric-double-bar (ADB), which was composed of only two bars with slightly different bar lengths, was used to obtain Fano resonance in the optical region. By changing the short bar length of ADB structures with high dimensional accuracy...
متن کاملRetinal Arteriolar Morphometry Based on Full Width at Half Maximum Analysis of Spectral-Domain Optical Coherence Tomography Images
OBJECTIVES In this study, we develop a microdensitometry method using full width at half maximum (FWHM) analysis of the retinal vascular structure in a spectral-domain optical coherence tomography (SD-OCT) image and present the application of this method in the morphometry of arteriolar changes during hypertension. METHODS Two raters using manual and FWHM methods measured retinal vessel outer...
متن کاملLED backlight designs with the flow-line method.
An LED backlight has been designed using the flow-line design method. This method allows a very efficient control of the light extraction. The light is confined inside the guide by total internal reflection, being extracted only by specially calculated surfaces: the ejectors. Backlight designs presented here have a total optical efficiency of up to 80% (including Fresnel and absorption losses) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advanced Materials
سال: 2021
ISSN: ['1521-4095', '0935-9648']
DOI: https://doi.org/10.1002/adma.202007162