Dedicated Algorithm for Unobtrusive Fetal Heart Rate Monitoring Using Multiple Dry Electrodes
نویسندگان
چکیده
منابع مشابه
Wireless ECG and Heart Rate Monitoring Using Dual Ground Dry Electrodes
In this work, a novel wireless easy-to-use measuring system is presented to acquire the Lead I ECG signal and the heart rate. The system presents a novel application of the dual ground configuration to dry electrodes, to reduce their level of power line interference. With this, a good quality Lead I EGC signal can be obtained simply by placing the right and left hands on the dual electrodes. He...
متن کاملFetal heart rate pattern notification guidelines and suggested management algorithm for intrapartum electronic fetal heart rate monitoring.
CONTEXT Numerous randomized controlled trials have demonstrated limited efficacy of intrapartum fetal heart rate monitoring in improving fetal outcome. A potential reason is the wide variability in clinical decision making seen with its use. Standardizing management of variant intrapartum fetal heart rate tracings may reduce this variability and lead to improvement in fetal outcome. OBJECTIVE...
متن کاملThe future of fetal heart rate monitoring.
Medical technology is developing at an accelerated rate. Advances and refinement in techniques of electronic fetal heart rate (FHR) monitoring are continually being designed and tested. Many of these show real promise for the future. Never-theless, for the next several years there are two major considerations. First, a more universal application of FHR monitoring i.e., to the "normal" patient ä...
متن کاملNovel dry electrodes for ECG monitoring.
The development, fabrication and characterization of two novel dry bioelectrodes--conductive and capacitive ones--for biopotential monitoring are presented. The new electrodes have the potential to improve the applicability of dry electrodes in ambulant recording of ECG by reducing motion artifacts as well as the contact impedance to the skin. Furthermore, a passive filter network is integrated...
متن کاملComment on the article "accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes".
OBJECTIVE Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. DESIGN Prospective open method equivalence study. SETTING Three urban teaching hospitals in the Northeast United States. SAMPLE 75 women with normal pregnancies in labor at >37 weeks of gestatio...