We present a case of a patient with chronic obstructive pulmonary disease whose myocardial perfusion SPECT imaging demonstrated diffusely decreased Tc-99m sestamibi lung uptake ("lucent lungs"); our results indicate that there may be a lower limit of normal for lung-to-heart ratio, below which pathology can be inferred.

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Relationship between the optimum cut off frequency for Butterworth filter and lung-heart ratio in 99mTc myocardial SPECT

Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically. Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be ...

متن کامل

myocardial perfusion spect: perfusion quantification

different software tools for quantification of myocardial perfusion spect (mps) studies are routinely used. several perfusion parameters can be computed automatically.  interpretation of the mps should start with visual inspection of the rotating planar images, visual analysis of reconstructed spect slices and then quantitative analysis to confirm the visual impression. quantification should be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiology Case Reports

سال: 2012

ISSN: 1930-0433

DOI: 10.2484/rcr.v7i1.636