Deadtime effects in quantification of 177Lu activity for radionuclide therapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deadtime effects in quantification of 177Lu activity for radionuclide therapy

BACKGROUND The aim of this study was to investigate the deadtime (DT) effects that are present in 177Lu images acquired after radionuclide therapy injection, assess differences in DT based on the full spectrum and the photopeak-only measurements, and design a method to correct for the deadtime losses. A Siemens SymbiaT SPECT/CT camera with a medium energy collimator was used. A 295-mL bottle wa...

متن کامل

SPECT image segmentation for estimation of tumour volume and activity concentration in 177Lu-DOTATATE radionuclide therapy

BACKGROUND Dosimetry in radionuclide therapy has the potential to allow for a treatment tailored to the individual patient. One therapeutic radiopharmaceutical where patient-specific dosimetry is feasible is 177Lu-DOTATATE, used for the treatment of neuroendocrine tumours. The emission of gamma photons by 177Lu allows for imaging with SPECT (single photon emission computed tomography). One impo...

متن کامل

Accuracy and precision assessment for activity quantification in individualized dosimetry of 177Lu-DOTATATE therapy

BACKGROUND In order to obtain a reliable 177Lu-DOTATATE therapy dosimetry, it is crucial to acquire accurate and precise activity measurements with the radionuclide calibrator, the SPECT/CT camera, and the NaI(Tl) well counter. The aim of this study was to determine, in a clinical context, the accuracy and the precision of their activity quantification over a range of activities and time. Ninet...

متن کامل

Targeted Radionuclide Therapy with A 177Lu-labeled Anti-HER2 Nanobody

RIT has become an attractive strategy in cancer treatment, but still faces important drawbacks due to poor tumor penetration and undesirable pharmacokinetics of the targeting vehicles. Smaller radiolabeled antibody fragments and peptides feature highly specific target accumulation, resulting in low accumulation in healthy tissue, except for the kidneys. Nanobodies are the smallest (MW<15 kDa) f...

متن کامل

In Vitro comparison of 213Bi- and 177Lu-radiation for peptide receptor radionuclide therapy

BACKGROUND Absorbed doses for α-emitters are different from those for β-emitters, as the high linear energy transfer (LET) nature of α-particles results in a very dense energy deposition over a relatively short path length near the point of emission. This highly localized and therefore high energy deposition can lead to enhanced cell-killing effects at absorbed doses that are non-lethal in low-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: EJNMMI Physics

سال: 2018

ISSN: 2197-7364

DOI: 10.1186/s40658-017-0202-7