DC-Link Voltage Research of Photovoltaic Grid-Connected Inverter Using Improved Active Disturbance Rejection Control

نویسندگان

چکیده

In this paper, a robust DC-link voltage control scheme is proposed to improve the tolerance of photovoltaic (PV) grid-connected inverter disturbances. The sensitive characteristic complicates dynamics system and limits its overall performance, especially when uncertain disturbances are considered. To cope with issue, controller based on linear active disturbance rejection (LADRC) designed. By exploring principle deviation regulation, an improved extended state observer (LESO) established ensure that total can be estimated in relatively timely manner. error feedback (LSEF) law generated compensate for disturbance, which reduces plant approximate canonical cascaded double integrator. stability capability LADRC further analyzed frequency domain. Finally, theoretical analysis experimental results confirm feasibility scheme.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltage Control of Three Phase Inverters by Using Active Disturbance Rejection Control

Control of three phase inverters has been an important issue in recent years. This paper proposes active disturbance rejection control (ADRC) scheme for controlling three phase inverters. The main advantage of ADRC that motivated us for using this controller for inverter is that it is model independent.  This controller is used in a double loop structure including an inner current loop and oute...

متن کامل

Voltage-Sensorless Control Scheme for a Grid Connected Inverter Using Disturbance Observer

A grid connected inverter usually requires voltage and current measurements to control the active and reactive powers as well as the inverter output currents. While voltage sensors are essential to obtain reliable information on the phase angle, these additional components certainly increase the production costs and complexity. In this paper, a voltage-sensorless control scheme for a grid conne...

متن کامل

Improved Power Control Using Optimal Adjustable Coefficients for Three-Phase Photovoltaic Inverter under Unbalanced Grid Voltage

Unbalanced grid faults will lead to several drawbacks in the output power quality of photovoltaic generation (PV) converters, such as power fluctuation, current amplitude swell, and a large quantity of harmonics. The aim of this paper is to propose a flexible AC current generation method by selecting coefficients to overcome these problems in an optimal way. Three coefficients are brought in to...

متن کامل

voltage control of three phase inverters by using active disturbance rejection control

control of three phase inverters has been an important issue in recent years. this paper proposes active disturbance rejection control (adrc) scheme for controlling three phase inverters. the main advantage of adrc that motivated us for using this controller for inverter is that it is model independent.  this controller is used in a double loop structure including an inner current loop and oute...

متن کامل

Grid-connected Inverter Model and Control Strategies for Photovoltaic Application

This paper describes the three-phase grid-connected inverter model for photovoltaic application. The inverter system model and control strategies are carried in MATLAB/SIMULINK environment. Utilizing both proportional-integral controllers for the control loops, and the sinusoidal pulse-width modulation switching signals generation technique for the IGBTs, the inverter control system capable of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2021

ISSN: ['2169-3536']

DOI: https://doi.org/10.1109/access.2021.3050191