Dataset of producing and curing concrete using domestic treated wastewater

We tested the setting time of cement, slump and compressive and tensile strength of 54 triplicate cubic samples and 9 cylindrical samples of concrete with and without a Super plasticizer admixture. We produced concrete samples made with drinking water and treated domestic wastewater containing 300, 400 kg/m(3) of cement before chlorination and then cured concrete samples made with drinking wate...

متن کامل

using treated domestic wastewater in concrete mixing

this document provides feasibility study of using treated domestic wastewater in concrete mixing. today, concrete is one of the most important construction materials. from first time that concert was used in construction materials, always the drinkable water used for concrete mixing water. domestic wastewater contains about 400 ppm of organic materials. after the treatment of wastewater, concen...

متن کامل

Domestic Wastewater Reuse in Concrete Using Bench-Scale Testing and Full-Scale Implementation

Demand for fresh water by the construction sector is expected to increase due to the high increase in the growth of construction activities in Jordan. This study aims to evaluate the potential of scale-up of the application of treated domestic wastewater in concrete from bench-scale to a full-scale. On the lab scale, concrete and mortar mixes using Primary and Secondary Treated Wastewater (PTW,...

متن کامل

Using olive mill wastewater to improve performance in producing electricity from domestic wastewater by using single-chamber microbial fuel cell.

Improving electricity generation from wastewater (DW) by using olive mill wastewater (OMW) was evaluated using single-chamber microbial fuel cells (MFC). Doing so single-chambers air cathode MFCs with platinum anode were fed with domestic wastewater (DW) alone and mixed with OMW at the ratio of 14:1 (w/w). MFCs fed with DW+OMW gave 0.38 V at 1 kΩ, while power density from polarization curve was...

متن کامل

Behaviour of Normal Concrete Using Superplasticizer under Different Curing Regimes

The performance of concrete primarily depends upon the type and ratio of its constituents, compaction, curing conditions and admixtures used during curing process. Part of this research emphasis to calculate the consequences on strength of concrete when water-cement ratio is constant and the increase in slump occurs with the increase in amount of superplasticizer by percentage. The rest of the ...