Data-Driven Control of LVDC Network Converters: Active Load Stabilization

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

robust stabilization for fuzzy network control systems with data drift

in this study, a robust controller is designed for fuzzy network control systems (ncss) using the static output feedback. delay and data packet dropout affect on the stability of network control systems, and therefore, the asymptotic stability condition is established considering delay and data packet dropout. delay is time-varying while the lower and upper bounds for delay is defined, and the ...

متن کامل

Sampled - Data Modeling , Analysis and Control of Load - Resonant DC - DC Converters in Variable Frequency Operation

heterogeneous and dynamic problems of engineering technology and systems for industry and government. ISR is a permanent institute of the University of Maryland, within the Glenn L. Martin Institute of Technology/A. James Clark School of Engineering. It is a National Science Foundation Engineering Research Center. Web site http://www.isr.umd.edu I R INSTITUTE FOR SYSTEMS RESEARCH TECHNICAL RESE...

متن کامل

Evaluation of Existing DC Protection Solutions on an Active LVDC Distribution Network under Different Fault Conditions

Low Voltage Direct Current (LVDC) distribution is considered as one of the new promising technologies for better integration of distributed generation, and supplying local loads in more efficient way compare to AC systems. However, DC protection is still considered as one of the outstanding challenges that holds back the wide deployment of LVDC in last mile utility applications. Most of existin...

متن کامل

A Performance Driven Switching Control of DC-DC Converters

This paper reports the application of the switching control method based on the controller performance assessment. The switching of the controllers are done based on the current control performances. The accepted controller has the best estimated performance of all controllers. Finally, the practically and utility of this idea are evaluated by the voltage control result of the DC-DC converters.

متن کامل

Active Cardiac Stabilization using H∞ Control Methodology

Beating heart surgery is an important milestone in cardiac surgery. This technique is currently made possible thanks to the use of passive mechanical stabilizers. Nevertheless, the commercially available stabilizers exhibit significant residual motion, which is inherent to their geometry. Recently, a novel active stabilizer based on a compliant structure has been designed. High-speed visual fee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Smart Grid

سال: 2020

ISSN: 1949-3053,1949-3061

DOI: 10.1109/tsg.2019.2949259