Data acquisition system for E-835 silicon detector
نویسندگان
چکیده
منابع مشابه
The Data Acquisition System for the Jade Detector
An outline of the data acquisition system for the JADE experiment at PETRA, DESY is presented. After describing the hardware configuration, we describe our guiding ideas for the design of the data acquisition system, which is followed by accounts of the implementation of real-time software, the data flow. the monitoring and detector control as well as the on-line event analysis and filtering. F...
متن کاملNovel Data Acquisition System for Silicon Tracking Detectors
We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System. This DAQ is realized with C++ code using object-oriented techniques. Track parameters for the beam particles were reconstructed using off-line analysis code and...
متن کاملThe Zeplin Ii Dark Matter Detector: Data Acquisition System and Data Reduction the Zeplin Ii Dark Matter Detector: Data Acquisition System and Data Reduction
ZEPLIN II is a two-phase (liquid/gas) xenon dark matter detector searching for WIMP-nucleon interactions. In this paper we describe the data acquisition system used to record the data from ZEPLIN II and the reduction procedures which parameterise the data for subsequent analysis.
متن کاملData acquisition and detector characterization of GEO600
K Kötter1,2, C Aulbert5, S Babak4, R Balasubramanian4, S Berukoff5, S Bose5, D Churches4, C N Colacino1,2, C Cutler5, K Danzmann1,2, R Davies4, R Dupuis3, A Freise1,2, H Grote1,2, G Heinzel1,2, M Hewitson3, J Hough3, H Lück1,2, M Malec1,2, S D Mohanty5, S Mukherjee5, S Nagano1,2, M A Papa5, D Robertson3, B S Sathyaprakash4, B F Schutz5, A M Sintes5, K A Strain3, I J Taylor4, A Vecchio6, H Ward3...
متن کاملThe E 791 Parallel Architecture Data Acquisition System
To collect data for the study of charm particle decays, we built a high speed data acquisition system for use with the E791 magnetic spectrometer at Fermilab. The DA system read out 24 000 channels in 50 μs. Events were accepted at the rate of 9 000 per second. Eight large FIFOs were used to buffer event segments, which were then compressed and formatted by 54 processors housed in 6 VME crates....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1999
ISSN: 0168-9002
DOI: 10.1016/s0168-9002(98)00912-7