Aspects of data acquisition system design

Analog-to-digital converters (ADCs) and digital-toanalog converters (DACs) play an important role in the design of data acquisition systems. ADCs are used to convert analog signals like the output from a temperature transducer, a radio receiver or a video camera into digital signals for processing. Conversely, DACs are used to convert digital signals back to analog signals. For example, the DAC...

متن کامل

Design of Acoustic Emission Data Acquisition System of Wood Damage

The acoustic emission (AE) signal of wood damage is a kind of weak and highfrequency signal. Hardware circuit design and software programming are necessary for the acoustic emission data acquisition. In order to carry out further analysis, it needs to be preprocessed. The preprocessing hardware system consists of preamplifier, filtering circuit, main amplification circuit and AD converting circ...

متن کامل

Design and implementation of a portable physiologic data acquisition system.

OBJECTIVE To describe and report the reliability of a portable, laptop-based, real-time, continuous physiologic data acquisition system (PDAS) that allows for synchronous recording of physiologic data, clinical events, and event markers at the bedside for physiologic research studies in the intensive care unit. DESIGN Descriptive report of new research technology. SETTING Adult and pediatri...

متن کامل

Design of the Data Acquisition System Based on STM32

With rapid development of modern society, the requirements for high precise temperature and humidity is growing rapidly, for example production, storage, transportation, environment etc., these all have strict requirements for temperature and humidity testing, so the real-time monitoring of temperature and humidity and alarm prompt is extremely important. In this paper, a temperature and humidi...

متن کامل

Design of a Data Acquisition System for Lass

LASS is formed of two large magnets (Fig. 2). The first is a superconducting solenoid having a field region approximately 12 ft long with B=25 kG in the beam direction. The incident beam passes through a 1 meter hydrogen target at the upstream end of this solenoid. The secondary particles resulting from an interaction are trapped in helical orbits in the solenoid and their momenta measured by m...

متن کامل