Data Acquisition System Applying TMO for GIS Preventive Diagnostic System
نویسندگان
چکیده
منابع مشابه
Data acquisition system for chemical kinetic studies
A microcomputer-interfaced data acquisition system for chemical kinetics (interfacing with laboratory analogue instruments) has been developed. Analogue signals from instruments used in kinetics experiments are amplifed by a wide-range adjustable high-gain operational amplifier and smoothed by an op-based filter, and then digitized at rates of up to 10(4) samples per channel by an ADC 0816 digi...
متن کاملWireless data acquisition system for IoT applications
This paper presents an innovative implementation of a data acquisition, which is able to communicate with a chest belt in order to obtain the heart rate value and accelerometer data from a EZ Chronos watch. The main goal of the work presented is to implement an embedded system, which can be used in various life assisted or medical applications. Keywords—Arduino; Internet of things; body sensor;...
متن کاملFast Data Acquisition System for Impedance Tomography
In the paper concept of the measurement (based on the sampling of potential differences during one period of the measuring signal) for impedance tomography data acquisition is described. Proposal of elimination of influence of dc electrochemical potential on data acquisition system is given in the paper as well. Thus suggested method enables increasing the rate of measurement. Results of experi...
متن کاملIntegrated Learning System for Data Acquisition
The paper presents an enhanced learning and training system in data acquisition. This new method is the result of an interactive process for enhancing the learning activities for the students. The system was built to meet a new concept: “integrated learning”, an approach that allows students to exercise their abilities in real applications. These applications are entirely specified, having well...
متن کاملSynchronous SSVEP Data Acquisition System
Steady State Visually Evoked Potentials have been known for several decades and they appear in the primary visual cortex of brain as a result of light stimulation of the sense of sight. In this article a simple method for electroencephalographic data acquisition is presented. The system is based on the DSM-51 unit connected to goggles with blinking diodes and Mindset-1000 EEG amplifier with 16 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The KIPS Transactions:PartA
سال: 2009
ISSN: 1598-2831
DOI: 10.3745/kipsta.2009.16a.6.481