Dangerous hyperkalaemia after analysis of arterial blood sample.
نویسندگان
چکیده
منابع مشابه
Apparent hyperkalaemia from blood sampled from an arterial cannula.
Blood samples were obtained from a radial artery cannula in a 60-yr-old man during coronary artery surgery. Serum potassium concentrations of 9.3, 8.4, and 7.4 mmol litre(-1) were obtained. A simultaneous venous blood sample gave a serum potassium concentration of 4.4 mmol litre(-1). The ECG was unchanged. After the arterial cannula was repositioned, subsequent blood samples gave expected range...
متن کاملInterpretation of Arterial Blood Gas
تجزیه و تحلیل گازهای خون اطلاعات مهمی را در مورد اکسیژناسیون شریانی و تعادل اسید - باز در دست ما قرار می دهد. در ک این داده ها بخشی اساسی از مراقبت پرستاری در اکثر بیماران است. هنوز برای بسیاری از پرستاران، تفسیر نتایج گازهای خون شریانی همانند یک جدول پیچیده بوده و در مواقعی که بررسی تمام نتایج در اسرع وقت مورد نیاز باشد، این مشکل بیشتر نمایان می شود.
متن کامل[Comparison of arterial blood sample kits].
Most inaccuracies in the analysis of gases and electrolytes in arterial blood samples are due to preanalytic factors, among which is the type of equipment used for blood collection. Our objective was to compare arterial blood gas sample kits used under clinical conditions and to evaluate the impact of delay in estimation on variability in results. In 2 types of study we compared 5 kits (Radiome...
متن کاملArterial blood gas analysis.
With increasing use of arterial blood gas analysis in various ward and other hospital settings to aid medical diagnosis and management, nurses who can interpret results are often able to initiate earlier interventions and understand the reasons for medical interventions. This article enables nurses to interpret such results.
متن کاملNewtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches
Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Pathology
سال: 1988
ISSN: 0021-9746
DOI: 10.1136/jcp.41.12.1339-a