Damping torque analysis for DC bus implemented damping control
نویسندگان
چکیده
منابع مشابه
DC Bus Implemented Damping Control – Part II: Battery Energy Storage Systems
W DU and H F WANG Southeast University, Nanjing, China Abstract – Damping torque analysis is a technique developed based on classical control theory for the excitation implemented damping control in power generation, which has been widely used in engineering practice since it was proposed. This paper proposes the damping torque analysis for DC bus implemented damping control in power transmissi...
متن کاملShip roll damping control
The technical feasibility of roll motion control devices has been amply demonstrated for over 100 years. Performance, however, can still fall short of expectations because of difficulties associated with control system designs, which have proven to be far from trivial due to fundamental performance limitations and large variations of the spectral characteristics of wave-induced roll motion. Thi...
متن کاملStabilization by Damping Control
In engineering practice, damping control is a usual method for stabilization. In this paper we consider nonlinear affine systems. We show that if there exists a feedback law which provides sufficiently fast convergence of trajectories (rational stabilization) then the system can also be stabilized by damping control. Our construction relies on a Liapunov function, which is basically defined as ...
متن کاملPower Oscillation Damping Using for the Control of Multi Machine and Bus System
This project proposes a novel objective function and algorithm to obtain a set of optimal power system stabilizer (PSS) parameters that include a feedback signal of a remote machine and local and remote input signal ratios for each machine in a Multi-machine power system under various operating conditions. A novel function called the damping scale is proposed and formulated as an objective func...
متن کاملA Control Strategy for DFIM to Minimize DC Bus Voltage Fluctuations and Torque Oscillations
The Direct Power Contro; has many advantages like it avoids the usage of integration of PWM voltages which leads to stable operation even at zero rotor frequency, it is position sensor less and hence will not depend on machine parameters like stator or rotor resistance. In case of network unbalance, if the system is operated with constant active and reactive powers, it leads to oscillations in ...