DAMAGE DETECTION OF MULTI-STOREY BUILDINGS USING RANDOM RESPONSE DATA FROM SHAKING TABLE TESTS
نویسندگان
چکیده
منابع مشابه
metrics for the detection of changed buildings in 3d old vector maps using als data (case study: isfahan city)
هدف از این تحقیق، ارزیابی و بهبود متریک های موجود جهت تایید صحت نقشه های قدیمی سه بعدی برداری با استفاده از ابر نقطه حاصل از لیزر اسکن جدید شهر اصفهان می باشد . بنابراین ابر نقطه حاصل از لیزر اسکنر با چگالی حدودا سه نقطه در هر متر مربع جهت شناسایی عوارض تغییر کرده در نقشه های قدیمی سه بعدی استفاده شده است. تمرکز ما در این تحقیق بر روی ساختمان به عنوان یکی از اصلی ترین عارضه های شهری می باشد. من...
Atrium-assisted Natural Ventilation of Multi-storey Buildings
Buoyancy-driven displacement natural ventilation in a simple multi-storey building structure is investigated. The storeys are connected to a common atrium and top-down-chimneys, and the internal heat gains of the storeys are represented by localised point heat sources on each floor. The heat sources generate thermal plumes which entrain the surrounding air and transport warm air upwards. Simple...
متن کاملOn-site greywater treatment and reuse in multi-storey buildings.
The paper presents a study of a pilot plant treating light greywater for seven flats. The pilot plant combines biological treatment (RBC) with physicochemical treatment (sand filtration and disinfection). The pilot plant produced effluent of excellent quality, meeting the urban reuse quality regulations, and was very efficient in TSS turbidity and BOD removal: 82%, 98% and 96%, respectively. CO...
متن کاملIs it necessary to measure impact sound insulation from 20 Hz in lightweight multi-storey buildings?
It has previously been notified that residents living in lightweight multi-storey family houses do not experience the impact sound insulation to be as good as in an equivalent concrete building despite the same single number rating, L’n,w+CI,50-2500. From a comprehensive national research program in Sweden, it was recently indicated that the lowest frequencies, 20-50 Hz, are crucial when it com...
متن کاملCritical Points of Prefabricated Reinforced Concrete Wall Systems of Multi-storey Buildings
With respect to the dissipation of energy through plastic deformation of joints of prefabricated wall units, the paper points out the principal importance of efficient reinforcement of the prefabricated system at its joints. The method, quality and amount of reinforcement are essential for reaching the necessary degree of joint ductility. The paper presents partial results of experimental resea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 1995
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.60.67_3