Cyclotron Instrumentation for Nuclear Spectroscopy at Medium Resolution in Energy
نویسندگان
چکیده
منابع مشابه
Characterization of low, medium and high energy collimators for common isotopes in nuclear medicine: A Monte Carlo study
Introduction:In an ideal parallel-hole collimator, thickness of septal material should be sufficient to stop more than 95% of incident photons. However, some photons pass the septa without interaction or experience scattering before they reach the detector. In this study, we determined different contribution of collimator responses consist of geometrical response, septal penetr...
متن کاملInstrumentation for Far-infrared Spectroscopy
Measurements of far-infrared spectra are made far more difficult than the corresponding measurement of midor near-infrared spectra because of the weakness of the source. The spectral energy density of a blackbody at 1400 K is almost 5800 times weaker at 10 cm 1, and about 60 times weaker at 100 cm 1, than it is at 1000 cm 1. Since the sensitivity of any measurement of a midor far-infrared spect...
متن کاملInstrumentation for Gamma-Ray Spectroscopy
The subject of ttis chapter is the function and operation of the components of a gamma-ray spectroscopy system. In Chapter 3 it was shown that the output pulse amplitude from most gamma-ray detectors is proportional to the energy deposited by the gamma ray. The pulse-height spectrum from such a detector contains a series of full-energy peaks superimposed on a continuous Compton background. Alth...
متن کاملA - 1 . Progress Report on Instrumentation for Biological Research at the 88 - Inch Cyclotron . . . . . . . . . . 3
of paper presented at the Eleventh Annual Meeting of the Radiation Research Sot-iety, Marquette University, Milwaukee, Wisconsin, May 26 to 29, 1963. DR .R UP NA TH JI( D R. RU PA K NA TH ) -18UCRL1068 3 Supplement A1 1 . DIFFUSION-GRAVITY-CONTROLLED E N 2 YME -SUBSTRATE REACTION
متن کاملData processing for atomic resolution electron energy loss spectroscopy.
The high beam current and subangstrom resolution of aberration-corrected scanning transmission electron microscopes has enabled electron energy loss spectroscopy (EELS) mapping with atomic resolution. These spectral maps are often dose limited and spatially oversampled, leading to low counts/channel and are thus highly sensitive to errors in background estimation. However, by taking advantage o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 1956
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.1715622