Cyclic testing of single bay confined masonry walls with various connection details
نویسندگان
چکیده
منابع مشابه
in-plane behavior of confined masonry walls with and without opening
confined masonry buildings are used in rural and urban areas of iran. they performed almost satisfactoryduring past moderate earthquakes of iran. there is not a methodology in iranian seismic code (standard 2800-3rdedition) to estimate their capacities quantitatively. in line with removing this constraint, an attempt is made to studyin-plane behavior of two squared confined masonry walls with a...
متن کاملHomogenization of Interlocking Masonry Walls
In a previous publication the authors proposed a continuous model for describing the mechanical behaviour of ‘Running Bond’ masonry walls. Here a different masonry structure is considered. This structure is ‘bi-atomic’ in the sense that its pattern consists in two kind of blocks with different. The homogenization by differential expansions technique is used for obtaining an equivalent Cosserat ...
متن کاملRetrofitting Masonry Walls with Carbon Mesh
Static-cyclic shear load tests and tensile tests on retrofitted masonry walls were conducted at UAS Fribourg for an evaluation of the newly developed retrofitting system, the S&P ARMO-System. This retrofitting system consists of a composite of carbon mesh embedded in a specially adapted high quality spray mortar. It can be applied with established construction techniques using traditional const...
متن کاملMasonry Infill Walls under Blast Loading Using Confined Underwater Blast Wave Generators (wbwg)
The vulnerability of the masonry envelop under blast loading is considered critical due to the risk of loss of lives. The dynamic behaviour of masonry infill walls subjected to dynamic out-of-plane loading was experimentally investigated in this work. Using confined underwater blast wave generators (WBWG), applying the extremely high rate conversion of the explosive detonation energy into the k...
متن کاملcyclic testing of steel chevron braces with vertically slotted beam connection
experimental tests were performed to study the seismic behavior and performance ofmodified steel chevron braced frame systems, which incorporate a vertical slotted connection(vsc) detail between the top of the braces and the floor beam above. the vsc detail isintended to prevent vertical load transfer to the beam and limit brace forces to thecompressive resistance of the members. full-scale qua...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of Earthquake Engineering
سال: 2014
ISSN: 1570-761X,1573-1456
DOI: 10.1007/s10518-014-9627-8