Cyclic Loading Test for Beam-to-Column Connections of Concrete Encased CFT Column
نویسندگان
چکیده
منابع مشابه
Analytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملperformance of exterior precast concrete beam-column dowel connections under cyclic loading
the present study focuses on the performance of precast concrete beam-column dowel connections subjected to cyclic loading by conducting experiments. in this study, one-third scale model of two types of precast and a monolithic beam-column connection were cast and tested under reverse cyclic loading. the precast connections considered for this study is a beam-column connection where beam is con...
متن کاملNumerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames
This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...
متن کاملnon-linear seismic behavior of concrete beam - column connections
a parametrik investigation was conducted to study the non-linear behavior of precast and cast-in-place reinforced concrete beam-column connections subjected to tabas seismic forces (1979). the behavior of these types of connections in a four stories structure with respect to strength, ductility , stiffness, and bond deterioration at the joint core are presented and discussed. calculation result...
متن کاملThe Effects of Internal and External Stiffeners on Hysteretic Behavior of Steel Beam to CFT Column Connections
This study focuses on performance of H-shaped steel beams to CFT column rigid connections. To this end, the effects of internal and external stiffeners on hysteretic behavior of connections were studied. Comparative numerical analyses carried out on eight different connections. To this end finite element models were prepared using ANSYS and nonlinear cyclic analyses carried out. Results of this...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Korean Society of Steel Construction
سال: 2014
ISSN: 1226-363X,2287-4054
DOI: 10.7781/kjoss.2014.26.1.055