Current density distribution in resistive fault current limiters and its effect on device stability

نویسندگان

چکیده

The increase of current uniformity along a resistive type superconductor fault limiter (R-SFCL) in the design this limiters is well perceived as an important issue. non-uniform distribution R-SFCL only increases some superconducting regions, result, conditions, certain parts undergo phase change that heat pressure those areas and causes breakdown destruction device. In paper, density distributions common patterns used R-SFCs constructions have been simulated investigated. To end, effective model proposed for to achieve highest harmonic over superconductors compared other patterns. simulation results Ansys Maxwell Software advocate appropriate satisfying performance model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability

Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...

متن کامل

selection of resistive and inductive superconductor fault current limiters location considering system transient stability

superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...

متن کامل

An Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques

The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...

متن کامل

Fault Current Limiters – Principles and Application

In this paper a new type electrical devices, designed for use in medium voltage and high voltage grids, has been explained – the fault current limiters. Their principals of operation and different structures have been proposed. The comparative analysis and their possibile estimation have been made.

متن کامل

Power flow analysis and optimal locations of resistive type superconducting fault current limiters

Based on conventional approaches for the integration of resistive-type superconducting fault current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the insertion of a step or exponential resistance that is determined by a predefined quenching time. In this paper, we expand the scope of the aforementioned models by considering the actual behaviour of an SFCL in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physica C-superconductivity and Its Applications

سال: 2021

ISSN: ['1873-2143', '0921-4534']

DOI: https://doi.org/10.1016/j.physc.2020.1353786