Cumulative beam breakup in linear accelerators with time-dependent parameters
نویسندگان
چکیده
منابع مشابه
Cumulative Beam Breakup in Linear Accelerators with Arbitrary Beam Current Profile*
An analytical formalism for the solution of cumulative beam breakup in linear accelerators with arbitrary beam current profile is developed. It is applied to obtain an expression for the transverse displacement of trains of finite bunches. The same formalism is used to investigate the beam breakup-enhanced displacement of beams caused by the misalignment of the deflecting structures or focusing...
متن کاملCumulative Beam Breakup due to Resistive - Wall Wake ∗
The cumulative beam breakup problem excited by the resistive-wall wake is formulated. An approximate analytic method of finding the asymptotic behavior for the transverse bunch displacement is developed and solved. Comparison between the asymptotic analytical expression and the direct numerical solution is presented. Good agreement is found. The criterion of using the asymptotic analytical expr...
متن کاملTheory and Suppression of Multibunch Beam Breakup in Linear Colliders
An analytic theory of cumulative multibunch beam breakup in linear colliders is developed. Included is a linear variation of transverse focusing across the bunch train as might be applied, e.g., by chirping the radiofrequency power sources or by using radiofrequency quadrupole magnets. The focusing variation saturates the exponential growth of the beam breakup and establishes an algebraic decay...
متن کاملMultibunch Beam Breakup in High Energy Linear Colliders’
The SLAC design for a next-generation linear collider with center-of-mass energy of 0.5 to 1.0 TeV requires that multiple bunches (10) be accelerated on each RF fill. At the beam intensity (1O’O particles per bunch) and RF frequency (11 to 17 GHz) required, the beam would be highly unstable transversely. Using computer simulation and analytic models, we have studied several possible methods of ...
متن کاملCommissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators
This study presents the beam data measurement results from the commissioning of three TrueBeam linear accelerators. An additional evaluation of the measured beam data within the TrueBeam linear accelerators contrasted with two other linear accelerators from the same manufacturer (i.e., Clinac and Trilogy) was performed to identify and evaluate any differences in the beam characteristics between...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Special Topics - Accelerators and Beams
سال: 2005
ISSN: 1098-4402
DOI: 10.1103/physrevstab.8.024402