CT Coronary Angiography: 256-Slice and 320-Detector Row Scanners

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

PURPOSE To determine radiation doses from coronary computed tomographic (CT) angiography performed by using a 320-detector row volume scanner and evaluate how the effective dose depends on scan mode and the calculation method used. MATERIALS AND METHODS Radiation doses from coronary CT angiography performed by using a volume scanner were determined by using metal-oxide-semiconductor field-eff...

متن کامل

Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

BACKGROUND AND PURPOSE Recently introduced 320-detector row CT enables whole brain perfusion imaging compared to a limited scanning area in 64-detector row CT. Our aim was to evaluate patient radiation exposure in comprehensive stroke imaging by using multidetector row CT consisting of standard CT of the head, CTA of cerebral and cervical vessels, and CTP. MATERIAL AND METHODS Organ doses wer...

متن کامل

256- and 320-row coronary CTA: is more better?

This editorial refers to ‘The diagnostic accuracy of 256row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease’, by S.-P. Chao et al., on page 1916 and ‘Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the noninvasive evaluation of significant coronary artery disease’, by F.R. de...

متن کامل

Novel 320‐slice multislice CT angiography as a gatekeeper for invasive coronary angiography

The diagnostic accuracy of 64‐slice CTA, currently the most widely used CTA system, has been well established by several multicenter studies [4–6]. In a recent prospective multicenter, multivendor trial by Meijboom and coworkers, high diagnostic accuracy of 64‐slice CTA was observed in the evaluation of 360 symptomatic patients with acute and stable angina [5]. On a per‐patient basis, the sensi...

متن کامل

Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Current Cardiology Reports

سال: 2010

ISSN: 1523-3782,1534-3170

DOI: 10.1007/s11886-009-0075-z