CT automated exposure control using a generalized detectability index
نویسندگان
چکیده
منابع مشابه
A Novel Image Structural Similarity Index Considering Image Content Detectability Using Maximally Stable Extremal Region Descriptor
The image content detectability and image structure preservation are closely related concepts with undeniable role in image quality assessment. However, the most attention of image quality studies has been paid to image structure evaluation, few of them focused on image content detectability. Examining the image structure was firstly introduced and assessed in Structural SIMilarity (SSIM) measu...
متن کاملThe Generalized NEQ and Detectability Index for Tomosynthesis and Cone-Beam CT: From Cascaded Systems Analysis to Human Observers.
PURPOSE In the early development of new imaging modalities - such as tomosynthesis and cone-beam CT (CBCT) - an accurate predictive model for imaging performance is particularly valuable in identifying the physical factors that govern image quality and guiding system optimization. In this work, a task-based cascaded systems model for detectability index is proposed that describes not only the s...
متن کاملDetectability of nondifferentiable generalized synchrony.
Generalized synchronization of chaos is a type of cooperative behavior in directionally coupled oscillators that is characterized by existence of stable and persistent functional dependence of response trajectories from the chaotic trajectory of driving oscillator. In many practical cases this function is nondifferentiable and has a very complex shape. The generalized synchrony in such cases se...
متن کاملAnatomical background and generalized detectability in tomosynthesis and cone-beam CT.
PURPOSE Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background "noise" in cascaded systems analysis of 2D and 3D imaging performance to yield "generalized" metrics of noise-equivalent quanta (NEQ) and detectability index as a...
متن کاملAutomated liver segmentation using multislice CT images
With practical applications of multislice CT, highspeed imaging has drastically become possible in recent years as compared with the past and imaging the liver twice during the time a patient holds his breath once has become possible in liver CT imaging using contrast media. Thus, three-dimensional images of two time phases differing in the circulatory state of a contrast medium are obtainable ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2018
ISSN: 0094-2405
DOI: 10.1002/mp.13286