CSI-EPT in Presence of RF-Shield for MR-Coils
نویسندگان
چکیده
منابع مشابه
The design of dedicated RF coils for mouse MR
Introduction MR imaging of mice in medical research has allowed for well controlled disease models for pharmokinetic and dynamic tests of new contrast and therapeutic agents. However, the volume of interest in mice is typically several orders of magnitude smaller than in humans, and concomitantly the number of spins that contribute to the signal in an MR exam will be substantially smaller, ther...
متن کاملSuperconducting RF Coils for Clinical MR Imaging at Low Field1
Rationale and Objectives. A number of recent reports in the MRI literature have established that substantial signal-tonoise ratio (SNR) gains can be achieved with small samples or low resonance frequencies, through the use of high-quality factor high-temperature superconducting (HTS) RF receive coils. We show the application of HTS coils to the imaging of human subjects with improved SNR compar...
متن کاملThe shielding of RF MRI coils using double-sided EMI shield
We present, here, a device for shielding the RF MRI coils to eliminate their undesired radiation, and to restore the natural resonant frequency f0 in the presence of a biological sample. It is presented for a planar surface RF MRI coil. Nonetheless, this approach is also valid for conformal coils as well. Introduction The influence of any biological sample on an RF MRI coil results in a shift o...
متن کاملNovel optically tunable capacitor for RF safe tuning and decoupling of intravascular MR coils
S. Weiss, T. Uelzen, G. Pantel, J. Mueller Philips Research Laboratories, Hamburg, Germany, Department of Micro Systems Technology, Hamburg University of Technology, Hamburg, Germany, MRI Devices Daum GmbH, Schwerin, Germany Objective: The motivation for the application of intravascular imaging coils is to gain high SNR images from a local area. To maximize SNR, proper tuning and matching of su...
متن کاملMR-EPT Reconstruction Using an Inverse Formulation
The electrical conductivity of soft tissues can be reconstructed from imaging with MR Electrical Properties Tomography (MR-EPT). The reconstruction method used here is based on an inverse problem formulation, with two advantages over a direct inversion approach: a) no spatial differentiation is needed and b) the regularization term determines the resolution of the reconstructed data. The proces...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Medical Imaging
سال: 2017
ISSN: 0278-0062,1558-254X
DOI: 10.1109/tmi.2017.2665688