Cs vapor microcells with Ne-He buffer gas mixture for high operation-temperature miniature atomic clocks
نویسندگان
چکیده
منابع مشابه
First-order cancellation of the Cs clock frequency temperature-dependence in Ne-Ar buffer gas mixture.
Through the detection of Coherent Population Trapping (CPT) resonances, we demonstrate the temperature-dependence cancellation of the Cs clock frequency in microfabricated vapor cells filled with a mixture of Ne and Ar. The inversion temperature at which the Cs clock frequency temperature sensitivity is greatly reduced only depends on the partial pressure of buffer gases and is measured to be l...
متن کاملMiniature vapor-cell atomic-frequency references
We propose a sub-millimeter-scale vapor-cell atomic-frequency reference based on a micromachined vapor cell, all-optical excitation, and advanced diode-laser technology. We analyze theoretically the performance of such a device as a function of cell size. Initial measurements on small-scale vapor cells support the theoretical treatment. © 2002 American Institute of Physics. @DOI: 10.1063/1.1494...
متن کاملDynamic Characteristics of VCSELs for Cs-Based MEMS Atomic Clocks
We have fabricated flip-chip-bondable vertical-cavity surface-emitting lasers (VCSELs) emitting at 894.6 nm wavelength for Cs-based atomic clock applications. For polarization control, we have integrated shallow semiconducting surface gratings in the top Bragg mirror. A modulation bandwidth of more than 5GHz is reached at only 0.5mA bias. Modulation current efficiency factors larger than 12GHz/...
متن کاملLaser Spectroscopy with Nanometric Cells Containing Atomic Vapor of Metal: Influence of Buffer Gas
Comparison of absorption and fluorescence in a nano-cell containing Rb vapor with other Rb nano-cells where neon gas is added is presented. The effect of collapse and revival of Dicke-type narrowing is still observable for the Rb nano-cells where Ne gas is added under 6 and 20 Torr pressure for the thickness L=/2 and L=, where is a resonant laser wavelength 794 nm (D1 line). Particularly fo...
متن کاملAtomic vapor cells for chip-scale atomic clocks with improved long-term frequency stability.
A novel technique for microfabricating alkali atom vapor cells is described in which alkali atoms are evaporated into a micromachined cell cavity through a glass nozzle. A cell of interior volume 1 mm3, containing 87Rb and a buffer gas, was made in this way and integrated into an atomic clock based on coherent population trapping. A fractional frequency instability of 6 x 10(-12) at 1000 s of i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2015
ISSN: 1094-4087