Crystal growth and detector performance of large size High-purity Ge crystals
نویسندگان
چکیده
منابع مشابه
Determination of Crystal Growth Rate and Morphology of Barium Carbonate Crystals in a Semi-batch Crystallizer
A semi-batch crystallization system is used to determine growth kinetics and morphology of barium carbonate crystals, under a constant pH value and constant temperature in the various relative supersaturations. Results show that crystal growth rate satisfies a first-order kinetic expression at high relative supersaturation, while at relative supersaturation values lower than 3, the k...
متن کاملApproach for growth of high-quality and large protein crystals
Three crystallization methods for growing large high-quality protein crystals, i.e. crystallization in the presence of a semi-solid agarose gel, top-seeded solution growth (TSSG) and a large-scale hanging-drop method, have previously been presented. In this study the effectiveness of crystallization in the presence of a semi-solid agarose gel has been further evaluated by crystallizing addition...
متن کاملPerformance of a Ge-microstrip imaging detector and polarimeter.
Using 98% linearly polarized radiation at the European Synchrotron Radiation Facility in Grenoble, the performance of a prototype two-dimensional microstrip Ge(i) detector for x-ray imaging and as a Compton polarimeter has been evaluated. Using the energy and position sensitivity of the detector, the ability to obtain a complete reconstruction of the Compton event has been demonstrated. The mod...
متن کاملThe Best Choice of High Purity Germanium (HPGe) Detector
below and are based on some basic concepts about how the detection process works, how gamma rays penetrate materials, and the principles of gamma-ray spectroscopy. Unresolved choice issues can be reduced to a level where they have little or no impact on the resultant performance of the spectrometry system. This document explains how you can easily make a wise, well-informed choice. We assume yo...
متن کاملPerformance of a Low-Background High Purity Germanium Detector with a Novel EndCap
Low background HPGe detectors have been used for many years in the measurement of low activities of radionuclides in various materials. With the increased importance of nuclear forensics, low background detectors are in increasing demand. The endcap and other materials used in low background detector construction must be selected to have the lowest activity possible. In some cases, the material...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materials Science in Semiconductor Processing
سال: 2015
ISSN: 1369-8001
DOI: 10.1016/j.mssp.2015.04.044