Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: I. Instrumentation, imaging and spectroscopy.
We have developed a cryo scanning transmission X-ray microscope which uses soft X-rays from the National Synchrotron Light Source. The system is capable of imaging frozen hydrated specimens with a thickness of up to 10 microm at temperatures of around 100 K. We show images and spectra from frozen hydrated eukaryotic cells, and a demonstration that biological specimens do not suffer mass loss or...
متن کاملQuantitative phase imaging with a scanning transmission x-ray microscope.
We obtain quantitative phase reconstructions from differential phase contrast images obtained with a scanning transmission x-ray microscope and 2.5 keV x rays. The theoretical basis of the technique is presented along with measurements and their interpretation.
متن کاملExperimental investigation of beam heating in a soft X-ray scanning transmission X-ray microscope.
A variable temperature sample holder with an operational range of 15 to 200 °C and an accuracy of ±1 °C has been fabricated for scanning transmission X-ray microscopes (STXM). Here we describe the device, and use it to image the polycrystalline morphology of solid stearic acid and palmitic acid at temperatures near their respective melting points as a means of checking for possible sample heati...
متن کاملX-ray spectromicroscopy with the scanning transmission X-ray microscope at BESSY II.
Using the scanning transmission X-ray microscope at BESSY II, colloidal structures from a Chernozem soil have been studied with a spatial resolution around 60 nm and a spectral resolution of 1,700 at the K-absorption edge of carbon. Elemental mapping has been used to determine the distribution of organic matter within the colloidal structures. Spectra have been extracted from image stacks to ob...
متن کاملX-ray Microanalysis of Cultured Cells in the Scanning Electron Microscope and in the Scanning Transmission Electron Microscope: a Comparison
X-ray microanalysis of cultured cells as “whole mounts” (i.e., not sectioned) is used frequently e.g., to study mechanisms of ion transport. Cells can be cultured either on solid substrates or on thin plastic films on grids. Cells cultured on solid substrates are analyzed in the scanning electron microscope at relatively low accelerating voltage, cells cultured on thin films can be analyzed in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2018
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.5041009