Cryo-Planing Vs Freeze Fracture: Sample Preparation for Cryo-HRSEM
نویسندگان
چکیده
منابع مشابه
A novel cryo-FIB lift-out procedure for cryo-TEM sample preparation
The focused-ion-beam (FIB) is the method of choice for site-specific sample preparation for Transmission Electron Microscopy (TEM) in material sciences. A lamella can be physically lifted out from a specific region of a bulk specimen with submicrometer precision and thinned to electron transparency for high-resolution imaging in the TEM. The possibility to use this tool in life sciences applica...
متن کاملMeasuring single-nanoparticle wetting properties by freeze-fracture shadow-casting cryo-scanning electron microscopy
Nanoparticles at fluid interfaces are central to a rapidly increasing range of cutting-edge applications, including drug delivery, uptake through biological membranes, emulsion stabilization and the fabrication of nanocomposites. Understanding nanoscale wetting is a challenging issue, still unresolved for individual nanoparticles, and is essential in designing nanoparticle-building blocks with ...
متن کاملAn introduction to sample preparation and imaging by cryo-electron microscopy for structural biology.
Transmission electron microscopy (EM) is a versatile technique that can be used to image biological specimens ranging from intact eukaryotic cells to individual proteins >150kDa. There are several strategies for preparing samples for imaging by EM, including negative staining and cryogenic freezing. In the last few years, cryo-EM has undergone a 'resolution revolution', owing to both advances i...
متن کاملA portable cryo-plunger for on-site intact cryogenic microscopy sample preparation in natural environments.
We present a modern, light portable device specifically designed for environmental samples for cryogenic transmission-electron microscopy (cryo-TEM) by on-site cryo-plunging. The power of cryo-TEM comes from preparation of artifact-free samples. However, in many studies, the samples must be collected at remote field locations, and the time involved in transporting samples back to the laboratory...
متن کاملOptimization of sample cooling temperature for redox cryo-imaging.
Cryo-imaging techniques have been widely used to measure the metabolic state of tissues by capturing reduced nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) autofluorescence. However, NADH and FAD fluorescence is sensitive to changes in temperature, which may result in unreliable redox ratio calculations. Here, the relationship between the measured redox ratio and...