Cryo-EXLO Manipulation of FIB Specimens for Cryo-TEM
نویسندگان
چکیده
Abstract This work describes cryogenic ex situ lift out (cryo-EXLO) of focused ion beam (cryo-FIB) thinned specimens for analysis by transmission electron microscopy (cryo-TEM). The steps and apparatus necessary cryo-EXLO are described. Methods designed to limit ice contamination include use an anti-frost lid, a vacuum transfer assembly, cryostat. Cryo-EXLO is performed in cryostat with the cryo-shuttle holder positioned vapor phase above surface liquid N2 (LN2) using EXLO manipulation station installed inside glove box maintained at < 10% relative humidity inert (e.g., gas) conditions. Thermal modeling shows that specimen will remain vitreous within its FIB trench indefinitely while LN2 continuously supplied. Once cut off, over 4 min, allowing sufficient time cryo-transfer which take only seconds perform. was applied successfully cryo-FIB-milled preparation polymer sample plunge-frozen yeast cells. Cryo-TEM both minimal maintaining phase, illustrating potential cryo-FIB-TEM beam-sensitive, liquid, or biological materials.
منابع مشابه
A novel cryo-FIB lift-out procedure for cryo-TEM sample preparation
The focused-ion-beam (FIB) is the method of choice for site-specific sample preparation for Transmission Electron Microscopy (TEM) in material sciences. A lamella can be physically lifted out from a specific region of a bulk specimen with submicrometer precision and thinned to electron transparency for high-resolution imaging in the TEM. The possibility to use this tool in life sciences applica...
متن کاملCryo-TEM of Polyelectrolyte-Micelle Complexes
Cryo-TEM was carried out on samples containing polyelectrolyte-micelle complexes, formed by combining poly(diallyldimethylammonium chloride) (PDADMAC), a strong cationic polyelectrolye, with oppositely charged mixed micelles of sodium dodecyl sulfate (SDS) and nonionic Triton X-100 (TX100), in 0.40 M NaCl. Complexation appears to involve the formation of micelle-rich regions, presumably within ...
متن کاملCryo-electron microscopy of vitrified specimens.
Present addresses: ' Centre de Microscopie Electronique (CME), 27 Rue du Bugnon, CH-105 Lausanne; Laboratoire Europeen de Biologie Moleculaire, I.L.L. 156X; F-38042 Grenoble Cedex; ' The Institute of Biophysics, Academica Sinica, Peking, China; 4 Institut de Biochimie, n Rue Humann, F-67000 Strasbourg; 5 Centre de Genetique Moleculaire, C.N.R.S., F-9H90 Gif/Yvette; 6 Howard Hughes Medical Insti...
متن کاملSkeletal muscle triad by FIB milling and Cryo-ET
Cryo-electron tomography (cryo-ET) has emerged as perhaps the only practical technique for revealing nanometer-level three-dimensional structural details of subcellular macromolecular complexes in their native context, inside the cell. As currently practiced, the specimen should be 0.10.2 microns in thickness to achieve optimal resolution. Thus, application of cryo-ET to intact frozen (vitreous...
متن کاملCryo-FIB Minimizes Ga Milling Artifacts in Sn
Since FIB was first introduced, one of the major applications has been to mill site-specific crosssectioned sample surfaces [1]. This approach not only allows SEM access to the structural information buried under the surface, but it is also the first step of making TEM lamellae using FIB. Importantly, there are many reports of beam-induced damage due to FIB processing. Here, we report on artifa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2023
ISSN: ['1435-8115', '1431-9276']
DOI: https://doi.org/10.1093/micmic/ozac029